• Nominal sizes
- 100 and 150.
• Execution
- A... direct mounting;
- B... surface mounting with clamp;
- C... back panel flush mounting;
- D... 2” pipe mounting;
- ...D dry;
- ...F liquid filled;
- ...P fillable.
• Casing
- case and ring in AISI 304 stainless steel (AISI 316 on request - option V61) with bayonet bezel.
• Protection degree (according to EN 60529)
- IP 55 for execution D;
- IP 67 for execution F and P.
• Window
- glass for execution D;
- methacrylate for execution F and P;
- laminated safety glass (on request - option V17).
• Casing filling liquid
- silicone fluid (standard).
• Pressure connections (according to EN 837)
o AISI 316L stainless steel:
- 1/4-18 NPT (1/4 NPT female) - standard;
- G 1/2 B (1/2 Gas or BSP male) or 1/2-14 NPT EXT (1/2 NPT male) (on request - option V43).
• Pressure element
- AISI 316L or Duratherm stainless steel diaphragm, according with selected ranges.
• Static pressure for all scale ranges, apart from the pressure entry in both connections:
- 100 bar (both ports)
• Overpressure
- 2 x full scale value on one port.
• Differential cell
o material:
- AISI 316L stainless steel.
• Diaphragm stop
- polyurethane resin.
• Differential cell bolts and nuts
- di acciaio inox AISI 304.
• Differential cell gaskets
- nitril rubber (NBR) standard;
- FPM (Viton) on request.
• Movement
- stainless steel.
• Torsion shaft
- stainless steel.
• Ranges (according to EN 837)
o Scale ranges for pressure values between 160 mbar and 25 bar:
- see table C1 at page P04; (divisions as per table C1 at page P04).
- other graduations not normalized for single or double range (on request).
o Unit of pressure:
- mbar, bar, kPa, kg/cm2 and psi for single or double range.
o Scale angle:
- 270 °.
note: scale angle is 180° with ranges 0 ÷ 160 mbar for model DP 370.
• Pointer
- aluminium with micrometer adjustment.
• Dial
- white aluminium with black figures (for dial modifications see available options).
• Accuracy (according to EN 837)
- class 1,6 (± 1,6% of full scale deflection).
note1: accuracy indicated on the pressure gauge does not consider the interference of an eventually applied electric contact.
note2: il diaphragm seal can affect instrument accuracy according with the service conditions because of the pressure/temperature ratio.
• Ambient temperature
- -30 ÷ +60 °C.
• Operating temperature
- max 120 °C.