Loading...

FANTINELLI Srl

Single diaphragm differential pressure gauges

DP 370-A  
DP 370-A

• Nominal sizes

- 100 and 150.


• Execution

- A... direct mounting;

- B... surface mounting with clamp;

- C... back panel flush mounting;

- D... 2” pipe mounting;

- ...D dry;

- ...F liquid filled;

- ...P fillable.


• Casing

- case and ring in AISI 304 stainless steel (AISI 316 on request - option V61) with bayonet bezel.


• Protection degree (according to EN 60529)

- IP 55 for execution D;

- IP 67 for execution F and P.


• Window

- glass for execution D;

- methacrylate for execution F and P;

- laminated safety glass (on request - option V17).


• Casing filling liquid

- silicone fluid (standard).


• Pressure connections (according to EN 837)

o AISI 316L stainless steel:

- 1/4-18 NPT (1/4 NPT female) - standard;

- G 1/2 B (1/2 Gas or BSP male) or 1/2-14 NPT EXT (1/2 NPT male) (on request - option V43).


• Pressure element

- AISI 316L or Duratherm stainless steel diaphragm, according with selected ranges.


• Static pressure for all scale ranges, apart from the pressure entry in both connections:

- 100 bar (both ports)


• Overpressure

- 2 x full scale value on one port.


• Differential cell

o material:

- AISI 316L stainless steel.


• Diaphragm stop

- polyurethane resin.


• Differential cell bolts and nuts

- di acciaio inox AISI 304.


• Differential cell gaskets

- nitril rubber (NBR) standard;

- FPM (Viton) on request.


• Movement

- stainless steel.


• Torsion shaft

- stainless steel.


• Ranges (according to EN 837)

o Scale ranges for pressure values between 160 mbar and 25 bar:

- see table C1 at page P04; (divisions as per table C1 at page P04).

- other graduations not normalized for single or double range (on request).

o Unit of pressure:

- mbar, bar, kPa, kg/cm2 and psi for single or double range.

o Scale angle:

- 270 °.

note: scale angle is 180° with ranges 0 ÷ 160 mbar for model DP 370.


• Pointer

- aluminium with micrometer adjustment.

• Dial

- white aluminium with black figures (for dial modifications see available options).

• Accuracy (according to EN 837)

- class 1,6 (± 1,6% of full scale deflection).

note1: accuracy indicated on the pressure gauge does not consider the interference of an eventually applied electric contact.

note2: il diaphragm seal can affect instrument accuracy according with the service conditions because of the pressure/temperature ratio.


• Ambient temperature

- -30 ÷ +60 °C.


• Operating temperature

- max 120 °C.

Indipendent diaphragm differential pressure gauges

  • DP 370
    • ranges included between 160 mbar and 25 bar;
    • static pressure100 bar;
    • scale angle 270°;
    • accuracy class 1,6.